The ITC Threshold Project — Statistical Defensibility for the Noetic Frontier
Free Beta Program · The American Paranormal

ITC NAMECOM FieldOps Statistical Field Monitoring Software

A rigorous, locally-executed anomaly monitoring instrument for paranormal field investigators. Real Mahalanobis distance scoring. Real chi-squared statistics. A 16-feature signal model. Runs entirely on your machine — no cloud, no subscription, no bullshit.

Important: This instrument measures statistical deviation from a calibrated environmental baseline. It does not establish source, agency, identity, or cause. Interpretation happens after measurement, using context and corroboration.

ITC NAMECOM FieldOps
LOCAL ONLY LIVE
Anomaly Score
0.842
elevated
p-Estimate
1.2e-04
empirical
CUSUM
0.176
bounded
Entropy H
0.913
bits/symbol
SIGNAL WITHIN NORMAL RANGE · MONITORING
PROCESS STATUS
Input Stream● receiving
Baseline Calibration● complete
Windowed Analysis● active
Anomaly Scoring● active
GUARD● READY
What It Is

A Field Instrument Built for Serious Investigators

Not another spirit box. Not another EVP recorder. A statistically rigorous measurement tool designed around how real anomaly detection actually works.

📡

Local Anomaly Monitoring

Runs entirely on your machine. No cloud processing, no data leaving your device. Your investigation data is yours.

📐

Real Statistical Analysis

Mahalanobis distance scoring across 16 signal features. Chi-squared significance testing. CUSUM persistence detection. Not scaled bar graphs — actual math.

🔒

Contamination Control

Every operator interaction triggers a 3-second scoring freeze. Any qualified event in your record cannot be attributed to you touching the computer.

📋

Auditable Session Records

SHA-256 seed commitment at session start proves your session was not fabricated. JSON, CSV, HTML, and methods document exports for every session.

🔁

Live vs. Control Protocol

Built-in session typing — LIVE vs. CONTROL — locked irrevocably at first scoring window. The methodological foundation for meaningful comparison.

How It's Different

Capability Older Approaches NAMECOM FieldOps
Statistical scoring Scaled display only Mahalanobis distance + chi-squared p-value
Baseline model None or implicit Explicit 60-sec calibration, frozen baseline
Operator contamination Not controlled 3-sec guard freeze on every UI interaction
Session integrity No verification SHA-256 seed commitment at session start
Persistence detection Single-window triggers CUSUM accumulator — requires sustained deviation
Control methodology Rare or informal Explicit LIVE/CONTROL session typing, locked
Export / review Screenshots JSON, CSV, HTML, methods doc — all events
How It Works

The Signal Pipeline

Six stages from input to event record. Each stage is mathematically defined and auditable.

1

Input Stream

Microphone captures real acoustic air-pressure fluctuations, or a synthetic noise source for pipeline testing. Sampled at 44.1kHz, processed in 500ms windows.

2

Baseline Calibration

Instrument collects 120 windows (60 seconds) of signal data. Computes mean and variance — or full 16×16 covariance matrix — of the undisturbed environment. Frozen. Never modified during a live session.

3

Feature Extraction

Each 500ms window produces a 16-dimensional feature vector: entropy, variance, drift, runs, autocorrelation, jitter, spectral flux, RMS amplitude, DC bias, tail weight, burst density, silence fraction, phase coherence, roughness, kurtosis, and spectral novelty.

4

Anomaly Scoring

Mahalanobis distance measures how far each window is from the calibrated baseline.

D² = (x − μ)ᵀ Σ⁻¹ (x − μ)
score = √(D²/k), k = 16

Under the null hypothesis, D² follows χ²₁₆. The p-value is the chi-squared survival probability.

5

CUSUM Persistence

A single anomalous window proves nothing. The CUSUM accumulator rewards sustained deviation across multiple windows while decaying in the absence of new evidence.

Cₜ = max(0, Cₜ₋₁ + eₜ − 0.72)

Isolated spikes cannot qualify. Consistent, repeated elevation is required.

6

Event Logging

A qualified event requires: score ≥ threshold for 3 consecutive windows, CUSUM ≥ 3.0, 15+ seconds since the prior event, and no operator freeze active. Each record includes all 16 feature values, exact p-value, CUSUM, timestamp, and session type.

The 16 Signal Features

What the Instrument Measures

entropy

Shannon Entropy

Frequency distribution randomness. Persistent low entropy in broadband noise is anomalous.

drift

Mean Drift

Signal stationarity within the window. Sustained drift indicates non-stationarity.

variance

Amplitude Variance

Spread of signal amplitude values within the 500ms window.

runs

Zero-Crossing Rate

Fraction of sign flips. Low runs = smooth DC-like signal, anomalous in noise.

autocorr

Autocorrelation

Lag-1 self-similarity. High autocorrelation suggests persistent periodic structure.

jitter

Timing Jitter

Irregularity of oscillation rhythm across sub-blocks within the window.

flux

Spectral Flux

Rate of change of frequency content between consecutive windows.

kurtosis

Kurtosis

Tail weight of amplitude distribution. Gaussian noise ≈ 0; impulsive noise is high.

novelty

Spectral Novelty

Distance of current spectrum from rolling mean of recent windows.

phase

Phase Coherence

Regularity of zero-crossing intervals. Low = regular oscillation, high = chaotic phase.

tail

Tail Fraction

Samples exceeding 3σ. Measures heavy-tailed statistical outliers within the window.

burst

Burst Density

Fraction of samples near peak amplitude. Episodic high-amplitude events.

The statistics describe deviation. They do not by themselves identify the cause. The instrument marks candidate moments for review — so patterns can be studied with discipline and humility.

16
Signal Features
per 500ms Window
χ²
Real Chi-Squared
p-Values
0
Data Leaves
Your Machine
v4.0
Current Release
Beta Program
Who It's For

Investigators Who Want Evidence, Not Theater

Built for fieldwork that can stand up to scrutiny — yours and anyone else's.

🔬

Research-Oriented Investigators

You want a repeatable methodology with documented baselines. You care about the difference between LIVE and CONTROL sessions. You want exports that can be reviewed by others.

📹

Content Creators & Teams

You want a professional-grade instrument on screen that reflects real science. The console is visually compelling and the underlying data is genuine — not a light show with no meaning behind it.

🧪

ITC Researchers

You're familiar with the PEAR Lab, the SPR literature, and what rigorous parapsychological methodology actually looks like. This instrument was designed with that standard in mind.

The Paranormal Working Hypothesis

Some investigators propose that consciousness, intention, or an unknown agency may modulate a noisy signal environment in measurable ways. This connects ITC methodology to the broader tradition of REG research — from the Princeton PEAR Lab's two decades of mind-matter interaction studies to Roger Nelson's Global Consciousness Project.

NAMECOM FieldOps is the measurement layer for this hypothesis. It marks candidate moments — statistically qualified deviations from baseline — for post-session review and comparison. The interpretation is yours. The instrument does not assume a cause.

Field Protocol

The Correct Workflow for a Session

Every live investigation should be paired with a matched control session. That comparison is where meaningful data lives.

Before You Arrive

  • ✓ Charge laptop fully
  • ✓ Test on synthetic source at home
  • ✓ Plan one control session and one live session at the location
  • ✓ Document environmental notes: HVAC, traffic, equipment in use

Control Session (Run First)

  • ✓ Declare session type: CONTROL
  • ✓ Select signal source: Audio (Mic)
  • ✓ Calibrate 60 seconds. Do not speak or move.
  • ✓ Start Live Watch. Leave the room or remain completely still for 20+ min.
  • ✓ Stop and export. Note any anomalies.

Live Session (Run Second)

  • ✓ Declare session type: LIVE
  • ✓ Re-calibrate in the same position
  • ✓ Start Live Watch
  • ✓ Conduct your investigation. Use Mark Moment for key activities.
  • ✓ Remain away from laptop — every touch triggers the contamination guard
  • ✓ Stop and export. Note timestamps of all activities.

After the Investigation

  • ✓ Compare live and control session statistics externally
  • ✓ Verify qualified event p-values are lower in the live session than control
  • ✓ Check the methods document for any drift warnings
  • ✓ Archive all four export files: JSON, CSV, HTML, Methods
  • ✓ The methods document is designed for independent technical review

The key principle: A single live session, however dramatic, proves nothing in isolation. What matters is whether the distribution of anomaly scores, event rates, and p-value distributions differs between live and control sessions conducted at the same location with the same equipment over equal durations. That comparison is what the session type lock is designed to protect.

System Requirements

What You Need to Run It

HARDWARE
ComputerWindows, macOS, or Linux. 4GB RAM minimum.
MicrophoneAny USB or built-in mic. Condenser preferred for spectral resolution.
BrowserChrome or Firefox. Opens to localhost:8787.
SOFTWARE
Python3.10 or later. Virtual environment recommended.
Packagesfastapi, uvicorn, numpy, scipy — all in requirements.txt
Optionalsounddevice for microphone. libportaudio2 on Linux.
NETWORK
Local onlyApp binds exclusively to 127.0.0.1. No outbound calls. Wi-Fi does not affect scoring.
RecommendedDisable Wi-Fi during sessions for maximum signal cleanliness.
Your dataNever leaves your machine. Ever.